Abstract

The results of an investigation concerning a mechanism of brittle fracture in glass reinforced plastic (GRP) rods used in non-ceramic insulators (NCI) are presented. Commercial grade GRP rods and GRP rods from actual insulators were exposed to ultra-pure water (UPW) and acids while being subjected to mechanical stresses. The experimental results revealed that water has the potential of inducing stress corrosion cracking on the fibers and hence brittle fracture in the rods. It is observed that the fracture proceeded faster when the rods were exposed to UPW than when exposed to acids. Furthermore, a brittle fracture in an epoxy cross-arm, which was installed in a region where the formation of acids in the atmosphere can be neglected, is analyzed. Based on these evidences, it is postulated that the failure of in-service NCI in the brittle mode can occur under the influence of water and mechanical stresses, and that the failure is more likely to happen with water than with acids.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.