Abstract

Methods for investigations of stresses specialized for devices operating up to 500°C are presented in this study. Resistive pressure sensors and test chips with microstrain (μ-strain) gauges are processed in thin film technology. The sensor structure was a Wheatstone bridge on a silicon membrane with platinum resistors. The μ-strain gauges were characterized with tensile tests in combination with optical strain measurements. A gauge factor of 3.6 was measured at room temperature. After characterization as bare dice, the chips were mounted with a borosilicate glass solder on two ceramic substrates, AlN and Si3N4. We generated a FE model of the sensor assemblies including temperature-dependent material properties. The distribution of mechanical strains and stresses in the sensor was analyzed. The chip warpage dependent on temperature up to 500°C was obtained from FE simulations and compared with high-precision 3D deformation measurements. Deformation results from digital image correlation (DIC) verified the utilized FE model. The correlation of experimental results for the chip warpage exhibited good agreement with the numerical results obtained from FEM. The chip deflection from the center to the edges in the out-of-plane direction on AlN was 4.5 μm; on Si3N4 a concave warpage of 3 μm at 25°C was found. Temperature-induced deformations of the sensor chip in the range of micrometers were recorded up to 500°C. The output signal of the pressure sensors is strongly affected by superimposed strains based on the sensor assembly. The bridge voltage increased by 40% after the glass solder process on AlN and by 34% for devices on Si3N4. The analysis of the μ-strain gauges showed compressive strains in the sensor membrane of −1.39% on average for assemblies on AlN and of −0.168% for glass soldered chips on Si3N4. The FEM simulations revealed an average in-plane stress in the sensor membrane of −45 MPa for chips on AlN and −20 MPa for Si3N4 substrates. The compressive strains in the membrane obtained by FEM were verified by the μ-strain gauge measurements. A higher strain and stress gradient in the membrane of devices on AlN was found with FEM, which is consistent with the higher signal offset of assembled pressure sensors that was measured in this study.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.