Abstract

A micro-compression test method was presented to evaluate the mechanical property of the TSV-Cu micropillar in this paper. Firstly, the test sample containing TSV-Cu micropillar was prepared by MEMS micromachining technology. Then, the mechanical property of TSV-Cu micropillar was measured by a self-made micro-compression system. Finally, the effect of thermal treatment on the mechanical property of TSV-Cu micropillar was studied. The experimental results showed that the average yield strength (σ0.2) of the TSV-Cu micropillar was 167 MPa. But it decreased to 137 MPa after being thermally treated at 400°C for 1 hour, which was probably due to the increased grain size of Cu.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.