The influence of thermal cyclic overloads on mechanical properties of winding conductors was investigated. Copper-niobium microcomposite, soft and hard pure copper wires were conditioned at temperatures range from 77 K to 500 K. The treatment was done during 100 cycles of fast conductor cooling to liquid nitrogen temperature and further fast heating in a climatic chamber. The ultimate tensile stress limit and the elongation at failure of metal-matrix copper-niobium microcomposite, soft and hard copper wires were measured before and after thermal treatment with a testing machine at room temperature.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.