Abstract
This paper aims to investigate the influence of exposure to cryogenic temperatures using liquid nitrogen on the mechanical properties of normal concrete (NC) and ultra-high-performance fiber-reinforced concrete (UHPFRC), which is commercially available. This research was carried out to examine the feasibility of using UHPFRC for a liquefied natural gas storage tank. For this, both compressive and direct tensile tests were performed at three different testing conditions: ambient temperature, cryogenic temperature (−170°C), and recovered ambient temperature after experiencing the cryogenic temperature. The test results showed that the compressive strengths of both NC and UHPFRC were noticeably increased at the cryogenic temperature compared with those at ambient temperature. However, there was no improvement in the tensile strength of NC at the cryogenic temperature, and its tensile strength was deteriorated after exposure to the cryogenic temperature. In contrast with NC, the tensile performance of UHPFRC significantly increased, including improvements in strength, post-cracking stiffness, and energy absorption capacity. Given the superior mechanical properties, it was concluded that UHPFRC is suitable for liquefied natural gas storage tanks.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.