Abstract

This paper describes the tensile test results of martensitic steels EUROFER 97 and T91 after exposure to flowing Pb–17Li and Pb–55.5Bi alloy, respectively. The corrosion tests were performed in LIFUS II loop (Pb–17Li) and LECOR loop (Pb–55.5Bi) located in the ENEA Brasimone Center. Tensile test were carried in SYNTECH test machine under Ar atmosphere with an extension rate of 2 mm/min, and test temperature for EUROFER and T91 steels were at 480 and 400 °C respectively. The exposure of EUROFER steel to the liquid Pb–17Li did not affect its mechanical properties, while the ductility of T91 steel was deteriorated after exposed to flowing liquid Pb–55.5Bi.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.