Abstract
Combining commercially available Polyglactin 910 (Vicryl) sutures with bioactive glass powder offers new possibilities for application of composite materials in tissue engineering. Commercial bioactive glass (45S5 Bioglass) powder was used to coat Vicryl sutures and the tensile strength of the sutures was tested before and after immersion in simulated body fluid (SBF) as a means to assess the effect of the bioactive glass coating on suture degradation. Different gauge lengths (126.6 and 111.6 mm) and strain rates (2.54, 11.4 and 25.4 mm/min) were tested. The tensile strength of composite sutures was slightly lower than that of as-received Vicryl sutures (404 MPa versus 463 MPa). However after 28 days immersion in SBF the residual tensile strength of the coated sutures was significantly higher, indicating a protective function of the Bioglass coating. The tensile strength results were similar for the different gauge lengths and strain rates investigated. A qualitative explanation for the effect of bioactive glass coating on polymer degradation is offered.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: Journal of Materials Science: Materials in Medicine
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.