Abstract

Microstructural observations of extrusion welds in an A-pillar made of AA6082-T4 revealed that the observed extrusion weld is a composite of a seam weld (longitudinal weld) and a charge weld (transverse weld). To determine the mechanical properties of this weld region, tensile specimens were prepared with the weld located at 0°, 45°, and 90° to the tensile axis. For comparison purposes, specimens from no-weld regions were also prepared in the same orientations and tested. The specimens with 45°-weld exhibited the lowest tensile strength, followed by the specimens with 90°-weld, no-weld and 0°-weld specimens. Comparison of failure strains and fracture modes revealed that weld regions are less ductile than the no-weld regions. Microscopic observations of fractured surfaces and further analysis revealed that Mg2Si precipitates that align along the charge weld cause premature failure at these locations.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.