Abstract
Ti and its alloys have the most satisfactory properties for biomedical applications due to their specific strength, high corrosion resistance, and high biocompatibility. Ti-6Al-7Nb has been approved for clinical use, proving to be a viable replacement for the Ti-6Al-4V alloy that has been used for many decades in medical applications. In our study, the Ti-6Al-7Nb alloy underwent heat treatment, was cooled in various cooling media such as mineral oil and water, and was then quenched in the oven. The microstructure was investigated, and the mechanical characterization was carried out by Vickers microhardness test. Young’s modulus measurements and tensile tests were performed in order to study the effect of cooling media on the material. To study the corrosion behavior, in vitro studies were performed on the Ti-6Al-7Nb samples in simulated body conditions by using artificial saliva. It was observed that the martensitic phase changed as a function of cooling media, and a less intensive cooling medium decreases strength properties’ indicators as well as hardness values. The results emphasize that the use of heat treatment improves the passive layer’s resistance in the presence of artificial saliva.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.