Abstract

The propagation of thermal runaway in a battery system is safety-critical in almost every application, such as electric vehicles or home storage. Abuse models can help to undestand propagation mechanisms and assist in designing safe battery systems, but need to be well-parametrized. Most of the heat during thermal runaway is released by venting that is why the characteristic of the vent flow plays an important part in the safety assessment. During venting, the cell generates a recoil force like a rocket, which depends on the flow speed and flow rate of the gas. This principle is used in this work to measure the velocity and mass flow rate of the vent gas. High-power and high-energy 18650 format lithium-ion batteries were overheated and the recoil and weight forces were measured to determine the venting parameter during thermal runaway. Our results show, that the linearized gas flow rate for the high-power and high-energy cell is 22.15gs−1 and 27.92gs−1, respectively. The progress of the gas velocity differs between the two cell types and in case of the high-energy cell, it follows a single peak asymmetrical pattern with a peak of 398.5ms−1, while the high-power cell shows a bumpy pattern with a maximum gas velocity of 260.9ms−1. The developed test bench and gained results can contribute insights in the venting behavior, characterize venting, support safety assessments, simulations and pack design studies.