Abstract

This paper presents the results of tests on mechanical properties, durability, short-term testing for creep, and drying shrinkage of recycled aggregate concrete (RAC). A natural aggregate concrete (NAC) mixture was designed for a characteristic compressive strength of 40 MPa (5.8 ksi) and the natural coarse aggregate (NA) was replaced by coarse recycled concrete aggregate (RCA) at 50, 75, and 100%. The existing concrete mixture design method was slightly modified to design the RAC mixtures, taking into account the lower specific gravity of the RCA. Fly ash was used as mineral admixture. The test results were compared with those of NAC and the NAC containing fly ash (NAF). The RAC exhibited comparable slump and strength to, and lower elastic modulus than, that of NAC. The resistivity was higher and chloride permeability was lower for RAC when compared to NAC; however, the same were inferior to NAF. The drying shrinkage strain of RAC mixture with 100% RCA was observed to be 1.24, 1.37, and 1.41 and creep strain was 1.15, 1.10, and 0.98 times that of NAC at 30 days, 60 days, and 90 days, respectively.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.