Abstract
Abstract Funding Acknowledgements Type of funding sources: None. Introduction Since coronary artery disease (CAD) is the leading cause of mortality in patients with end-stage renal failure, early detection of CAD in these patients presenting with still normal left ventricular (LV) systolic function is of clinical importance. Aim To investigate the correlation between electrical and mechanical dispersion and CAD in dialysis patients with normal LV systolic function. Material and methods: This prospective study included 78 dialysis patients who underwent a 12-channel electrocardiogram and echocardiographic examination to determine electrical and mechanical myocardial dispersion. A coronary calcium score using cardiac computed tomography was also assessed in a group of 20 patients without known CAD. Electrical dispersion was defined as the difference between the longest and shortest corrected QT interval (QTc). Mechanical dispersion (MD) was defined as either standard deviation of mechanical contraction duration of all LV segments (MD_SD) or the difference between the longest and shortest duration of mechanical contraction (MD_delta). The duration of mechanical contraction was determined by myocardial strain analysis. Results Previously known CAD was present in 11 (14%) patients, while pathologic Q wave was absent in all patients. No significant correlation was observed between QTc dispersion and both MD parameters (p > 0.05 for both). Both MD parameters (p = 0.007 for MD_SD; p = 0.026 for MD_delta), but not electrical dispersion (p = 0.584), showed a discriminative power for detecting previously known CAD (Figure). In patients without known CAD, neither QTc dispersion nor MD_SD showed a correlation with coronary calcium score (p > 0.05 for both). MD_delta showed a strong correlation with both total and coronary calcium score in the territory of the left anterior descending coronary artery (r = 0.62; p = 0.004) in patients without previously known CAD. Conclusion Mechanical dispersion is associated with known CAD in dialysis patients with normal LV systolic function. The range of mechanical myocardial contraction duration (MD_delta) correlates with subclinical coronary atherosclerosis. Figure. Discriminative power of mechanical and electrical dispersion for the detection of coronary artery disease Abstract Figure.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.