Abstract

The mechanical, electrochemical, wear, and corrosive-wear behaviors of a TiZrCuPd bulk glassy alloy were investigated. The Ti-based glassy alloy demonstrates a high yield strength of 2.3 GPa, low Young's modulus of 95 GPa, and Vickers microhardness of 7.2 GPa, which are superior to those of the Ti-6Al-4V biomedical alloy. The TiZrCuPd glassy alloy shows a good corrosion resistance in the phosphate buffer saline (PBS) solution, owing to the formation the Ti- and Zr-enriched passivation film on the alloy surface. The TiZrCuPd alloy displays the lowdry-wear rate of 6.1 × 10−8 mm3 mm N−1and wet-wear rate of 8.0 × 10−8 mm3 mm N−1. The triobocorrosionresults illustrate that the TiZrCuPd alloyshows a high pitting corrosion resistance during the wet sliding, which render its good corrosive wear performance. The good combination of mechanical, corrosion, and wear properties of the Ti-based glassy alloy make it promising for biomedical applications.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.