Abstract

With the aim of understanding failure modes in the peeling of silicone-based adhesive joints and, in particular, the occurrence of adhesive or cohesive failure, an experimental campaign has been conducted by considering plastic substrates with different surface roughness. A flexible strip has been bonded onto such substrates using a silicone adhesive, by controlling its thickness. Peeling tests with 90° and 180° peeling angle configurations have been performed and the effect of joint parameters, such as surface roughness and adhesive thickness, onto the adhesion energy and the failure mode are herein discussed in detail. Experimental results show that the failure mode varies in each peeling test configuration such that in the case of 180° peeling test there is mainly cohesive failure, while for 90° peeling angle, a combination of adhesive and cohesive failure occurs. Moreover, due to the presence of different failure modes in each peeling configuration, the substrate roughness can increase the adhesion energy only in 90° peeling tests.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.