Abstract
Abstract: This short technical note summarizes some recent data from hot dip galvanized steel bolted connections under fatigue loading. In particular the effect of a galvanizing coating on the fatigue strength of S355 structural steel is analyzed in detail showing that the decrease of the fatigue life is very limited if compared with that of uncoated joints and the results are in good agreement with Eurocode detail category, without substantial reductions. The procedure for the preparation of the specimens is systematically described in this note providing a useful tool for engineers involved in similar practical applications. The results are compared with previous data from notched galvanized specimens weakened by a central hole and not treated specimens characterized by the same geometry.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.