Abstract
The shield driven method is now a preferred choice when urban subway tunnels are constructed. In high density cities, a suitable cross-section for tunnel structures is rather important. In this study, a full-scale ring test is conducted in order to determine the mechanical behavior of Quasi-rectangular segmental tunnel linings, firstly designed and employed in Metro Line 3 in Ningbo, China. The design of experimental specimens and loading processes are introduced. Main results of tests are explored, including the failure state and measurement items, convergence deformation, strain of rebars, bending angle of joints and bolts’ strain .The ultimate bearing capacity of the structure is also reached during the test. According to the experimental results, two analysis methods are utilized to evaluate the mechanical behavior of the structure under design condition. The bearing mechanism and weakness of the lining are revealed as well. Safety factor of elastic stage and ultimate stage are also defined to evaluate safety reservation of the structure under unexpected circumstance. The test will lay the foundation for further verification and optimization of Quasi-rectangular segmental tunnel linings.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.