Abstract

BackgroundMore studies include multiple generations of the Actigraph activity monitor. So far no studies have compared the output including the newest generation and investigated the impact on the output of the activity monitor when enabling the low frequency extension (LFE) option. The aims were to study the responses of four generations (AM7164, GT1M, GT3X and GT3X+) of the Actigraph activity monitor in a mechanical setup and a free living environment with and without enabling the LFE option.MethodsThe monitors were oscillated in a mechanical setup using two radii in the frequency range 0.25-3.0 Hz. Following the mechanical study a convenience sample (N = 20) wore three monitors (one AM7164 and two GT3X) for 24 hours.ResultsThe AM7164 differed from the newer generations across frequencies (p < 0.05) in the mechanical setup. The AM7164 produced a higher output at the lower and at the highest intensities, whereas the output was lower at the middle intensities in the mid-range compared to the newer generations. The LFE option decreased the differences at the lower frequencies, but increased differences at the higher. In free living, the mean physical activity level (PA) of the GT3X was 18 counts per minute (CPM) (8%) lower compared to the AM7164 (p < 0.001). Time spent in sedentary intensity was 26.6 minutes (95% CI 15.6 to 35.3) higher when assessed by the GT3X compared to the AM7164 (p < 0.001). Time spend in light and vigorous PA were 23.3 minutes (95% CI 31.8 to 14.8) and 11.7 minutes (95% CI 2.8 to 0.7) lower when assessed by the GT3X compared to the AM7164 (p < 0.05). When enabling the LFE the differences in the sedentary and light PA intensity (<333 counts*10 sec-1) were attenuated (p > 0.05 for differences between generations) thus attenuated the difference in mean PA (p > 0.05) when the LFE option was enabled. However, it did not attenuate the difference in time spend in vigorous PA and it introduced a difference in time spend in moderate PA (+ 3.0 min (95% CI 0.4 to 5.6)) between the generations.ConclusionWe observed significant differences between the AM7164 and the newer Actigraph GT-generations (GT1M, GT3X and GT3X+) in a mechanical setup and in free-living. Enabling the LFE option attenuated the differences in mean PA completely, but induced a bias in the moderate PA intensities.

Highlights

  • The Actigraph (Pensacola, FL) activity monitors have been, and are, widely used in large population studies for the objective assessment of physical activity (PA) [1,2,3,4]

  • The mean counts per minute (CPM) for the GT3X without the low frequency extension (LFE) enabled was 18 CPM (8%) lower compared to the AM7164 (p < 0.001)

  • As a mean CPM can be compiled through different intensity distributions, we investigated whether the four participants differed from the remaining sample

Read more

Summary

Introduction

The Actigraph (Pensacola, FL) activity monitors have been, and are, widely used in large population studies for the objective assessment of physical activity (PA) [1,2,3,4]. Studies have compared the first two generations of Actigraph activity monitor; the AM7164 and the GT1M in mechanical [6], laboratory setups [7,8,9], and free-living conditions [10] and to our knowledge only one study have included the third generation GT3X in comparison to the GT1M [11]. No studies have compared the output including the newest generation and investigated the impact on the output of the activity monitor when enabling the low frequency extension (LFE) option. The aims were to study the responses of four generations (AM7164, GT1M, GT3X and GT3X+) of the Actigraph activity monitor in a mechanical setup and a free living environment with and without enabling the LFE option

Objectives
Methods
Results
Discussion
Conclusion