Abstract
ITER correction coils (CCs) feeder is the important component of ITER feeder systems to supply the cryogens and electrical power for CCs. They should withstand the huge electromagnetic (EM) force and high thermal shrinkage. Considering the EM and thermal loads, mechanical analysis is performed to qualify the structural strength of the lower CC feeder. Results show that containment duct and cryopipe can meet the static criteria but busbar jacket cannot meet. It is proposed that more supports should be added at the corners for the busbar. Basically, the lower CC feeder design is valid and feasible.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.