Abstract

A method for determining the mass size distribution of organic and black carbon (OC and BC) in atmospheric aerosols is introduced. The method relies on a particle sampling with 2 parallel size-segregating devices, a 12-stage Small Deposit area low pressure impactor (SDI) and a virtual impactor (VI), and the subsequent analysis of the samples with thermal and thermal-optical methods, respectively. The method development revealed that SDI is, like other sampling methods, susceptible to serious sampling artifacts and OC pyrolysis during thermal analysis. However, some of the SDI's limitations can be overcome by parallel VI measurements. The good correlation between the SDI and the VI data for most of the samples collected here indicates that under most conditions, the lack of the pyrolysis correction for the SDI samples does not cause significant errors in the OC/BC split. Valuable features of this method are that it offers a good size resolution in both sub- and supermicron size fractions, indicates if ther...

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.