Abstract

Measuring sedimentation rate of magnetorheological fluids (MRFs) is of great importance when designing and synthesizing MRFs for engineering applications. A method of characterizing sedimentation rate in an MRF column is proposed utilizing thermal conductivity correlated with particle concentration. A series of MRF samples composed of carbonyl iron particles suspended in silicone oil were prepared, and their concentrations (measured as volume fraction, ∅) and thermal conductivities, k, were tested. A calibration curve was developed to relate particle concentration, ∅, to thermal conductivity, k, using this set of MRF samples with known concentration. The particle concentration, ∅, in the MRF column was then monitored by measuring thermal conductivities (k) at a fixed location and using this calibration relationship. Finally, sedimentation rate in the MRF column was determined by examining how particle concentration varied with time. The sedimentation rate measured in the MRF column was validated using visual observation of mudline (boundary between the topmost clarified fluid zone and MRF below).

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.