Abstract

BackgroundCurrently, the accepted effective method for assessing blood volume status, such as measuring central venous pressure (CVP) and mean pulmonary artery pressure (mPAP), is invasive. The purpose of this study was to explore the feasibility and validity of the ratio of the femoral vein diameter (FVD) to the femoral artery diameter (FAD) for predicting CVP and mPAP and to calculate the cut-off value for the FVD/FAD ratio to help judge a patient’s fluid volume status.MethodsIn this study, 130 patients were divided into two groups: in group A, the FVD, FAD, and CVP were measured, and in group B, the FVD, FAD, and mPAP were measured. We measured the FVD and FAD by ultrasound. We monitored CVP by a central venous catheter and mPAP by a Swan-Ganz floating catheter. Pearson correlation coefficients were calculated. The best cut-off value for the FVD/FAD ratio for predicting CVP and mPAP was obtained according to the receiver operating characteristic (ROC) curve.ResultsThe FVD/FAD ratio was strongly correlated with CVP (R = 0.87, P < 0.0000) and mPAP (R = 0.73, P < 0.0000). According to the ROC curve, an FVD/FAD ratio ≥ 1.495 had the best test characteristics to predict a CVP ≥ 12 cmH2O, and an FVD/FAD ratio ≤ 1.467 had the best test characteristics to predict a CVP ≤ 10 cmH2O. An FVD/FAD ratio ≥ 2.03 had the best test characteristics to predict an mPAP ≥ 25 mmHg. According to the simple linear regression curve of the FVD/FAD ratio and CVP, when the predicted CVP ≤ 5 cmH2O, the FVD/FAD ratio was ≤ 0.854.ConclusionIn this study, the measurement of the FVD/FAD ratio obtained via ultrasound was strongly correlated with CVP and mPAP, providing a non-invasive method for quickly and reliably assessing blood volume status and providing good clinical support.

Highlights

  • The accepted effective method for assessing blood volume status, such as measuring central venous pressure (CVP) and mean pulmonary artery pressure, is invasive

  • We studied another non-invasive method for volume status assessment: the femoral vein diameter (FVD)/femoral artery diameter (FAD) ratio

  • According to the R values obtained from this experiment, the FVD/FAD ratio was strongly correlated with CVP (R = 0.87) and mean pulmonary artery pressure (mPAP) (R = 0.73)

Read more

Summary

Introduction

The accepted effective method for assessing blood volume status, such as measuring central venous pressure (CVP) and mean pulmonary artery pressure (mPAP), is invasive. The purpose of this study was to explore the feasibility and validity of the ratio of the femoral vein diameter (FVD) to the femoral artery diameter (FAD) for predicting CVP and mPAP and to calculate the cut-off value for the FVD/FAD ratio to help judge a patient’s fluid volume status. MPAP is an important index for evaluating pulmonary circulation volume status [3]. It is invasively measured with a pulmonary artery catheter (PAC), which needs to be monitored in an intensive care unit (ICU) and cannot provide fast and effective support for clinical work [4]. Given the above shortcomings of invasive assessment methods, a non-invasive, rapid, and effective method for assessing blood volume status is urgently needed

Objectives
Methods
Results
Discussion
Conclusion