Abstract

Sediment on the bottom of borehole forms a major part which is often responsible for reducing the bearing capacity of pile. The normal method of measuring sediment thickness by ultrasonic signal is to measure the sound time and intensity of echo signal. This paper presents a novel measurement method by estimating the ultrasonic channel. Wiener filter is applied to estimate the ultrasonic optimal channel under minimum mean square error criteria. Experiments of estimating channel based on Wiener filter have been conducted with given signals and actual ultrasonic detection echo. The influence of noise in the signal has been discussed. The results show that, during signals high SNR, the estimated channel is corresponding to the sharp changes in the actual signal and can be used to determine the sediment thickness.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.