Abstract

Constant infusion is a method used for measuring protein synthesis rate in living object which uses low concentration of amino acid tracers. Flooding dose method is another technique used to measure the rate of protein synthesis which uses labelled amino acid together with large amount of unlabelled amino acid. The latter method was firstly developed to solve the problem in determination of precursor pool arise from constant infusion method. The objective of this writing is to compare the results from several researches on measuring protein synthesis rate using flooding dose and constant infusion methods and to obtain the criteria or prerequisite on the type of sample and tracer for each method. The measurements of protein synthesis rate using both methods are presented and results from both methods are compared. Both methods are eligible for measuring protein synthesis rate as long as the true precursor can be measured. The uncertainties in determining the precursor in constant infusion method and the effect of flooding on the stimulation of protein are the limitation on using the two methods. Bolus injection which imitates the flooding dose method but using smaller dose of tracer can be a good alternative in measuring protein synthesis rate.

Highlights

  • Proteins are synthesized by incorporating amino acids in special order which is determined by the genes

  • There are two methods which widely used to measure the rate of protein synthesis: flooding dose method and constant infusion or trace dose method

  • Constant infusion method uses trace dose of amino acid tracer which is constantly infused to the tissue or cells for several hours [411]

Read more

Summary

Infusion Methods

Abstract— Constant infusion is a method used for measuring protein synthesis rate in living object which uses low concentration of amino acid tracers. Flooding dose method is another technique used to measure the rate of protein synthesis which uses labelled amino acid together with large amount of unlabelled amino acid. The latter method was firstly developed to solve the problem in determination of precursor pool arise from constant infusion method. The objective of this writing is to compare the results from several researches on measuring protein synthesis rate using flooding dose and constant infusion methods and to obtain the criteria or prerequisite on the type of sample and tracer for each method. Bolus injection which imitates the flooding dose method but using smaller dose of tracer can be a good alternative in measuring protein synthesis rate

INTRODUCTION
MATERIAL AND METHODS
Study Protocols
Sample Processing and Analysis
AND DISCUSSION
Method
CONCLUSION
Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call