Abstract
In this letter, an atom-based approach for measuring the microwave (MW) cavity response (including cavity frequency and Q-factor) is presented, which utilizes a MW magnetic field detection technique based on atomic Rabi resonances. We first identify the Rabi resonances on seven π transitions in Cs atoms and demonstrate their uses in continuously frequency-tunable field detectors. With the atom-based field detectors, we then indicate the possibility of reconstructing the MW cavity response by measuring the MW frequency-dependent Rabi frequency (i.e., MW field strength) inside the cavity. To demonstrate this approach, we measured the response curves of a 9.2-GHz cavity and a cavity resonating at 8.3 GHz and 9.7 GHz using π transitions and σ transitions, respectively. We compared the results measured by our approach with those measured by Vector Networker Analyzer and obtained good agreement. From such atom-based, SI-traceable measurements, the MW cavity response can be linked directly to the Rabi frequency, which could be referred to an atomic clock.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.