Abstract

Described are the results from studies done to provide test methods for state and local air pollution control agencies to measure accurately the lead emissions from stationary source stacks as required in the National Ambient Air Quality Standard for Lead. Separate test methods were developed for measuring inorganic lead and alkyl lead compounds. Inorganic lead is collected in a standard particulate sampling train, digested with 50% (V/V) nitric acid and 3% hydrogen peroxide and analyzed by atomic absorption spectrometry. Alkyl lead compounds are collected in iodine monochloride and analyzed by atomic absorption spectrometry without prior solvent extraction. Standard solutions of inorganic lead in dilute nitric acid are used to calibrate the spectrophotometer in both methods. The inorganic lead test method was evaluated using baghouse dust samples from a primary copper and a primary lead smelter and stack samples from a lead recovery furnace, a primary battery manufacturing plant, a gray iron foundry and ...

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.