Abstract
<p>This thesis introduces a methodological approach for assessing Indoor Environmental Quality (IEQ) at an unprecedented scale in a large property portfolio to identify good and poor IEQ in buildings to inform design, asset management, maintenance, and evidence-based policy decisions. There is clear evidence that with deteriorating IEQ conditions, there is a decrease in human performance and their acceptability of the indoor environment. This thesis initially sought to find precedents for the influence of combined IEQ (lighting, temperature, relative humidity, acoustics, and indoor air quality) measurements on learning performance in schools and found none. No standards for measuring or characterizing this all inclusive IEQ in classrooms was found. In previous IEQ studies, there is no coherent guidance on representative placement of sensors (data loggers) and height to place a multi-variable sensor within a space. </p> <p>The primary purpose of this thesis was to ascertain whether a one-point sensor measurement could be representative of the environmental condition across a space and where might be the best location to measure IEQ in many classrooms. Using the New Zealand Ministry of Education portfolio as a case study, physical measurements and observations were carried out in three typical case study classrooms, in three selected schools in Wellington. An array of sensors that simultaneously measures all five IEQ variables in a single device were deployed on the vertical walls and on the horizontal measuring plane in the case study classrooms during non-school days and school days in summer, autumn, and spring. One external sensor was positioned outside the classroom in a shaded walkway to monitor external environmental data and external weather data was also retrieved from the closet weather station. </p> <p>The main conclusion is that for all five environmental variables, the relationship between the central horizontal plane and vertical wall sensors was consistent for approximately 80% of the time. This indicated that a vertical wall sensor can reliably predict IEQ levels at the centre of a classroom. This study concludes that a one-point sensor located on an unglazed vertical wall, where the sun is unlikely to shine and away from any sources of heat can strongly predict IEQ at the most frequently occupied parts of a space (the centre). </p> <p>A one-point measurement provides an indication of what is happening in a room, but not necessarily all the variations (differences) across the room. The use of a one-point sensor gives a general indication of IEQ trends and patterns. It can suggest that IEQ highs are way too high or the lows way too low, or the range of extremes are too broad. It cannot pinpoint problem causes, or specific local issues, but is useful to triage good and poor IEQ in classrooms for early discrimination from hundreds or more classrooms of how to direct the maintenance or refurbishment programmes for large groups of school buildings. An additional level of information could be picked up better by using multiple sensors, building modelling or in combination with other qualitative methods such as survey of occupants. These findings can be used by researchers, architects, building scientist and policymakers to diagnose building performance in a national school property portfolio. The same process could be used in any large property portfolio to prioritize remediation works. </p>
Highlights
Indoor Environmental Quality (IEQ) as a phrase is typically used to refer to the quality of the conditions inside a building’s environment in relation to the comfort, health, and wellbeing of its occupants
The visual illuminance pattern of most horizontal plane sensors in classroom B were like the visual illuminance pattern of the long and short walls compared to classroom A which shows a difference in illuminance patterns between the horizontal plane and the vertical wall sensors
Given that the sun rises from east to west, the variation in illuminance patterns in the east facing sensors F1, 2, 3 and E3 show that as the sun moves during the course of a day, there is an increase in illuminance levels, which peaks around noon before decreasing when the sun moves towards the west
Summary
Indoor Environmental Quality (IEQ) as a phrase is typically used to refer to the quality of the conditions inside a building’s environment in relation to the comfort, health, and wellbeing of its occupants. Many variables influence this aspect of the quality of the indoor environment including external conditions (air pollution, external temperature), building (construction materials, furniture), building services (HVAC systems) and people and activities (HVAC use, cleaning), etc., (Almeida et al, 2015). A child spends about hours in school buildings yearly (52 (weeks) - 16 (vacation weeks) x 5 (days per week) x 5
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.