Abstract

Background: The aim of this paper was to assess and compare the accuracy of common magnetic resonance imaging (MRI) pulse sequences in measuring the lesion sizes of hepatocellular carcinomas (HCCs) with respect to the Milan criteria and histopathology as a standard of reference. Methods: We included 45 patients with known HCC who underwent contrast-enhanced MRI of the liver prior to liver transplantation or tumor resection. Tumor size was assessed pathologically for all patients. The MRI protocol contained axial T2-weighted images as well as T1-weighted imaging sequences before and after application of Gd-EOB-DTPA. Tumor diameters, the sharpness of lesions, and the presence of artifacts were evaluated visually on all available MRI sequences. MRI measurements and pathologically assessed tumor dimensions were correlated using Pearson’s correlation coefficient and Bland–Altman plots. The rate of misclassifications following Milan criteria was assessed. Results: The mean absolute error (in cm) of MRI size measurements in comparison to pathology was the smallest for the hepatobiliary phase T1-weighted acquisition (0.71 ± 0.70 cm, r = 0.96) and largest for the T2w turbo-spin-echo (TSE) sequence (0.85 ± 0.78 cm, r = 0.94). The misclassification rate regarding tumor size under the Milan criteria was lowest for the T2w half-Fourier acquisition single-shot turbo spin-echo sequence and the hepatobiliary phase T1w acquisition (each 8.6%). The highest rate of misclassification occurred in the portal venous phase T1w acquisition and T2w TSE sequence (each 14.3%). Conclusions: The hepatobiliary phase T1-weighted acquisition seems to be most accurate among commonly used MRI sequences for measuring HCC tumor size, resulting in low rates of misclassification with respect to the Milan criteria.

Highlights

  • Hepatocellular carcinoma (HCC) is the most common primary liver cancer in adults and the third leading cause of cancer-related deaths worldwide, with more than 700,000 newly diagnosed cases per year and an increasing incidence in western countries [1,2]

  • The aim of this study was to evaluate the diagnostic performance of different magnetic resonance imaging (MRI) pulse sequences in measuring HCC lesions, including the hepatobiliary phase T1-weighted acquisition with liver-specific contrast agent, and to evaluate their accuracy using histopathology as the reference standard

  • The lowest sensitivity for visualizing HCC was achieved with the T2w half-Fourier acquisition single-shot turbo spin-echo (HASTE) sequence (90%)

Read more

Summary

Introduction

Hepatocellular carcinoma (HCC) is the most common primary liver cancer in adults and the third leading cause of cancer-related deaths worldwide, with more than 700,000 newly diagnosed cases per year and an increasing incidence in western countries [1,2]. The aim of this paper was to assess and compare the accuracy of common magnetic resonance imaging (MRI) pulse sequences in measuring the lesion sizes of hepatocellular carcinomas (HCCs) with respect to the Milan criteria and histopathology as a standard of reference. Results: The mean absolute error (in cm) of MRI size measurements in comparison to pathology was the smallest for the hepatobiliary phase T1-weighted acquisition (0.71 ± 0.70 cm, r = 0.96) and largest for the T2w turbo-spin-echo (TSE) sequence (0.85 ± 0.78 cm, r = 0.94). The misclassification rate regarding tumor size under the Milan criteria was lowest for the T2w halfFourier acquisition single-shot turbo spin-echo sequence and the hepatobiliary phase T1w acquisition (each 8.6%). Conclusions: The hepatobiliary phase T1-weighted acquisition seems to be most accurate among commonly used MRI sequences for measuring HCC tumor size, resulting in low rates of misclassification with respect to the Milan criteria

Objectives
Methods
Results
Discussion
Conclusion
Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.