Abstract
We report a unique low-cost technique for measuring gain and noise figure (NF) in erbium-doped fiber amplifiers using a broad-band amplified spontaneous emission source and a transmission filter, by extracting the slope and intercept of output power spectral density versus input power spectral density at filter edges. The required filter depth is 30 dB. Discrepancies of /spl les/0.3 dB are found between gain or NF obtained from this technique and those measured using conventional spectral-interpolation technique employing multiple lasers at 100-GHz spacing across the C-band.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.