Abstract

BackgroundEcological momentary assessment (EMA) is an in situ method of gathering self-report on behaviors using mobile devices. In typical phone-based EMAs, participants are prompted repeatedly with multiple-choice questions, often causing participation burden. Alternatively, microinteraction EMA (micro-EMA or μEMA) is a type of EMA where all the self-report prompts are single-question surveys that can be answered using a 1-tap glanceable microinteraction conveniently on a smartwatch. Prior work suggests that μEMA may permit a substantially higher prompting rate than EMA, yielding higher response rates and lower participation burden. This is achieved by ensuring μEMA prompt questions are quick and cognitively simple to answer. However, the validity of participant responses from μEMA self-report has not yet been formally assessed.ObjectiveIn this pilot study, we explored the criterion validity of μEMA self-report on a smartwatch, using physical activity (PA) assessment as an example behavior of interest.MethodsA total of 17 participants answered 72 μEMA prompts each day for 1 week using a custom-built μEMA smartwatch app. At each prompt, they self-reported whether they were doing sedentary, light/standing, moderate/walking, or vigorous activities by tapping on the smartwatch screen. Responses were compared with a research-grade activity monitor worn on the dominant ankle simultaneously (and continuously) measuring PA.ResultsParticipants had an 87.01% (5226/6006) μEMA completion rate and a 74.00% (5226/7062) compliance rate taking an average of only 5.4 (SD 1.5) seconds to answer a prompt. When comparing μEMA responses with the activity monitor, we observed significantly higher (P<.001) momentary PA levels on the activity monitor when participants self-reported engaging in moderate+vigorous activities compared with sedentary or light/standing activities. The same comparison did not yield any significant differences in momentary PA levels as recorded by the activity monitor when the μEMA responses were randomly generated (ie, simulating careless taps on the smartwatch).ConclusionsFor PA measurement, high-frequency μEMA self-report could be used to capture information that appears consistent with that of a research-grade continuous sensor for sedentary, light, and moderate+vigorous activity, suggesting criterion validity. The preliminary results show that participants were not carelessly answering μEMA prompts by randomly tapping on the smartwatch but were reporting their true behavior at that moment. However, more research is needed to examine the criterion validity of μEMA when measuring vigorous activities.

Highlights

  • Ecological momentary assessment (EMA), known as the experience sampling method, is used to measure behaviors of people in natural settings [1]

  • When comparing microinteraction ecological momentary assessment (μEMA) responses with the activity monitor, we observed significantly higher (P

  • The same comparison did not yield any significant differences in momentary PA levels as recorded by the activity monitor when the μEMA responses were randomly generated

Read more

Summary

Introduction

Ecological momentary assessment (EMA), known as the experience sampling method, is used to measure behaviors of people in natural settings [1]. The repeated EMA prompts, which typically ask about momentary behaviors or states, reduce recall biases present in retrospective surveys [3,4] and capture temporal changes in health behaviors unique to each individual [5] Because of these benefits, EMA is commonly used to measure behaviors in intensive longitudinal studies [6]. Participants are first interrupted with a beep and/or vibration They must find the phone, unlock the device, and respond to a set of complex multiple-choice questions. Prior work suggests that μEMA may permit a substantially higher prompting rate than EMA, yielding higher response rates and lower participation burden. This is achieved by ensuring μEMA prompt questions are quick and cognitively simple to answer. The validity of participant responses from μEMA self-report has not yet been formally assessed

Methods
Results
Discussion
Conclusion
Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.