Abstract

The effects of steps on the transition of laminar boundary layers were measured on a flat plate for low Reynolds numbers with critical and subcritical step heights. The transition position was measured by determining the intermittency distribution in streamwise direction, including the characteristic length of the transitional region. The results are compared with formulations of a critical step Reynolds number {textrm{Re}_textrm{h}}, i.e., the step height that will instantly trigger transition at the step position, and—for subcritical step heights—with {{Delta N}}-formulations from the literature. For backward-facing steps, the concept of a step Reynolds number can be used to distinguish between subcritical and critical step heights, whereas for forward-facing steps there seems not to be one unique {textrm{Re}_textrm{h}}. Furthermore, for subcritical backward-facing steps the concept of a {{Delta N}}-approximation gives a reasonable description of the experimental observations. Again in contrast, for forward-facing steps a {{Delta N}}-approach scattered a lot and no clear dependency was found between the reduction in the critical N-factor of transition and the relative step height.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.