Abstract
In Q-band, dielectric losses and radiation losses of flexible circular PTFE waveguides are measured with parameters such as operating frequency, areas of the dielectric region in guiding cross sections, and radii of curvature. The dielectric losses of the rod and tube waveguides show relatively good agreement with theoretical results. The radiation losses of the guides, which current theory cannot predict in the regime of small radius of curvature, are measured from differences between insertion losses and the dielectric losses. The validity of our results can be explained by the fractional power flow ratios in each region of the waveguides.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.