Abstract

A new type of passive integrating cup monitors was developed by using a 50 mm radius stainless steel hemisphere to measured indoor radon (222Rn) and thoron (220Rn) concentrations. By placing a pair of cup monitors with an air exchange opening of diameter 5 mm and four openings of diameter 20mm at a 20cm distance from wall during about three months, the concentrations of both gases could be assessed from the a track densities on the cellulose nitrate (CN) films. The 222Rn and 220Rn concentrations were surveyed with the cup monitors in the different types of dwellings around Nagoya in Japan over three years. The 220Rn concentrations were rather high in the dwellings with soil wall, and the mean 220Rn concentration was 160±12 Bq·m−3. The 220Rn exhalation rate from wall and the 220Rn diffusion were evaluated from the distribution of 220Rn concentrations in the dwellings. The results of the surveys have also clarified the relationship between the 220Rn concentrations a t a 20cm distance from wall and the 220Rn...

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.