Abstract

The stability margin of a single quadruplex of Nb/sub 3/Sn/Cu composite strand enclosed in a round stainless-steel tube was measured by using an inductive heater whose duration time is around 0.1 ms. The strand had a diameter of 1.04 mm and a copper fraction of 69%. The fraction of helium in the cable space was 34.5%. Measurements of the stability margin were carried out by varying the transport current, external magnetic field, and initial helium pressure. The helium flow rate was always zero. The limiting transport current, which is the boundary value between the upper and lower stable regions similar to NbTi cable-in-conduit conductors, was observed. The limiting-current density over the cable space inside the conduit at 12 T was 100 A/mm/sup 2/, corresponding to 58% of the critical current. This value does not depend on the initial helium pressure in the range of 3-12 atm. Observed upper and the lower stability margins were more than 200 mJ/cm/sup 3/ strand and less than 60 mJ/cm/sup 3/ strand, respectively. The heat transfer coefficient in the cable-in-conduit conductor is estimated to be around 0.1 W/cm/sup 2/K. >

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.