Abstract

A 1/20-scale, low speed model rig representing the fan and nacelle of a high bypass ratio jet engine has been tested under crosswind conditions. The flow conditions under which the intake flow separates and reattaches have been found to exhibit considerable hysteresis. This phenomenon has been examined by a careful test procedure in which the crosswind angle has been slowly increased and then decreased. Measurements of the hysteresis associated with separation and reattachment are presented for independent variations in stream-tube contraction ratio, ground clearance, fan operating point and Reynolds number. The results reveal that particular care must be taken to allow for any hysteresis when testing intakes under crosswind conditions. They also indicate that separation hysteresis is particularly sensitive to fan operating point and the position of the ground plane. These findings suggest that it is important for high Reynolds number intake tests and calculations to include a ground plane and a model of the downstream turbomachinery. © 2002 by the author(s).

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.