Abstract
The extremely low-frequency (ELF) magnetic field emissions of seven video display terminal (VDT) models were measured. A measuring coil with a linearized frequency response (50 Hz to 25 kHz) was used. The dominating ELF magnetic field around the terminals was the 50 or 60 Hz asymmetric triangular waveform from the vertical deflection coil of the cathode ray tube. At the distance of 50 cm, the magnetic field strength was still slightly higher than the background level in usual office rooms, but several orders of magnitude lower than the thresholds of known interaction mechanisms. Some recent experiments suggest that certain biological effects may occur at field strengths only a few times higher than those found at the position of VDT operators, but the significance of these effects to human health is not known.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: Scandinavian journal of work, environment & health
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.