Abstract

Abstract The thrust loading on a vertical blowdown stack during a natural gas blowdown was investigated using a combined experimental and modeling approach. A gravimetric vessel initially at 4000 kPa-g was blown down through two geometrically different stack assemblies. Thrust loads were measured using a dynamic weigh scale typically used for gravimetric calibration of gas flow meters. A one-dimensional (1D) compressible flow model, calibrated using the experimental data, revealed stagnation pressure losses at the entrance to the riser, resulting in lower thrust loads. A comparison between thrust loading obtained from the measurements and the 1D compressible flow model is presented. This work shows that the analytical flow model predicts the blowdown thrust loads within ±30%.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.