Abstract

A method of measuring all the complex permeability tensor components of microwave ferrites using a single cylindrical ferrite sample is described. Two dielectric ring resonators having the same height and internal diameter but different external diameters, operating on HE/sub 111//sup +or-/ and H/sub 011/ modes respectively, are applied for these measurements. Permeability tensor components are computed from the measured resonant frequencies and Q factors of these resonators with and without the ferrite sample. Computations are based on the exact eigenvalue equations for these modes. Measurements of all permeability tensor components versus static magnetic field intensity, performed for different ferrite materials, generally confirm results obtained by earlier researchers, but they also contain certain aspects concerning relations between particular permeability tensor components below saturation.< <ETX xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">&gt;</ETX>

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.