Abstract This article presents simulation data and measurements of a novel valve concept that features a soft landing concept. The purpose is to validate the design framework that has been applied to design the valve. The experimental results are obtained with a test rig manufactured specifically for this type of valve design. The validation includes studying the valves switching dynamics, cushion pressure dynamics, and movement-induced flow (MIF). The tests show that the tendencies are captured accurately although the exact magnitudes of forces do not match fully and a noticeable difference between simulated and measured plunger position is revealed. This amounts in a significant difference in the cushion pressure. Therefore, the pressure model is validated by using the measured lift and velocity derived hereof and this shows sufficient correspondence between the two pressures.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.