Abstract

To investigate positive and negative thermophoretic effects for polystyrene latex (PSL) spheres of diameter between 0.3 and 0.8 μm, the average deposition velocity toward a horizontal wafer surface in vertical airflow is measured keeping the wafer surface temperature different from the surrounding air temperature. The temperature difference ranges from -10° to 4°C. The number of particles deposited on a wafer surface is obtained from the measurements by using a wafer surface scanner (PMS SAS-3600). Experimental data of particle deposition velocity are compared with those given by the prediction model to validate the model. Since thermophoresis changes greatly the particle deposition velocity, temperature difference necessary for the particle deposition velocity to remain under a given value is sought as a means to control the deposition velocity. The minimum temperature differences required to keep the average deposition velocity smaller than 10−4cm/s and 10−5 cm/s in a clean room environment are suggeste...

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.