Abstract
The purpose of our study was to determine the measurement uncertainty of ISO CD 23351-2 draft standard. Two sub-studies were conducted. In study 1, an accuracy experiment was conducted where 7 participants tested in the same room (in situ) two different products (full enclosure and partial enclosure). In study 2, an experiment was conducted where a single participant tested two different products in several rooms varying in room volume and reverberation time. Study 1 yielded an in-situ reproducibility standard deviation of 0.80.9 dB. Study 2 yielded a between-site standard deviation of 0.7 dB. The small standard deviations suggest that the technical content should not be essentially changed in the next versions of the standard. The results could be considered in next version of the standard ISO DIS 23351-2.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: INTER-NOISE and NOISE-CON Congress and Conference Proceedings
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.