Abstract
AbstractThis paper reports the development of a method for simultaneously measuring zeolite, silicate, and phosphate in laundry detergent products by inductively coupled plasma atomic emission spectrometry. A sample is decomposed under alkaline oxidative conditions to decompose zeolite, silicate, phosphate, and organic substances. Then hydrochloric acid is added to the decomposed solution to dissolve aluminum hydroxide precipitate before analysis. This sample preparation procedure was investigated by using a total organic carbon analyzer and was confirmed to be applicable to simultaneous measurements of zeolite, silicate, and phosphate. Relative standard deviation for the analysis is less than 2.1%, recovery is more than 99.0%, and the calibration curve gives a correlation coefficient ofR=1.000. The detection limit of this method for aluminum and silicon is 0.1%, and for phosphorus, 0.2% by weight in the product. This method is applicable to various laundry detergent products that contain zeolite, silicate, or phosphate and is five times faster than the three wet chemical methods.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.