Abstract
In wire electrical discharge machining (EDM), increase of the wire temperature influences the wire breakage during machining because the increase of the temperature leads to the decrease in mechanical strength of the wire electrode. In this study, in order to measure the wire temperature during wire EDM, a two-color pyrometer with an optical fiber was used. Experimental results showed that the infrared light radiated from the wire electrode during machining could be detected by the two-color pyrometer, and the temperature of wire electrode could be measured. The output ratio increased with the increase of discharge frequency, which means that the temperature of the wire electrode increased with increasing the discharge frequency.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.