Abstract

Dosimetry of small fields (SF) is vital for the success of highly conformal techniques. IAEA along with AAPM recently published a code of practice TRS-483 for SF dosimetry. The scope of this paper is to investigate the performance of three different detectors with 10 MV with-flatting-filter (WFF) beam using TRS-483 for SF dosimetry and subsequent commissioning of the Eclipse treatment planning system (TPS version-13.6) for SF data. SF dosimetry data (beam-quality TPR 20,10(10), cross-calibration, beam-profile, and field-output-factor (F.O.F)) measurements were performed for PTW31006-pinpoint, IBA-CC01 and IBA-EFD-3G diode detectors in nominal field size (F.S) range 0.5 × 0.5cm2 to 10 × 10 cm2 with water and solid water medium using Varian Truebeam linac. However, Eclipse-TPS commissioning data was acquired using IBA-EFD-3G diode, and absolute dose calibration was performed with FC-65G detector. The dosimetric performance of the Eclipse-TPS was validated using TLD-LiF chips, IBA-PFD, and IBA-EFD-3G diodes. Dosimetric performance of the PTW31006-pinpoint, IBA-CC01, and IBA-EFD-3G detectors was successfully tested for SF dosimetry. The F.O.Fs were generated and found in close agreement for all F.S except 0.5 × 0.5cm2. It is also found that TPR20,10(10) value can be derived within 0.5% accuracy from a non-reference field using Palmans equation. Cross-calibration can be performed in F.S 6 × 6 cm2 with a maximum variation of 0.5% with respect to 10 × 10cm2. During profile measurement, the full-width half-maxima (FWHM) of F.S 0.5 × 0.5cm2 was found maximum deviated from the geometric F.S. In addition, Eclipse-TPS was commissioned along with some limitations: F.O.F below F.S 1 × 1cm2 was ignored by TPS, PDD and profiles were dropped from configuration below F.S 2 × 2 cm2, and F.O.F which does not satisfy the condition 0.7 < A/B < 1.4 (A and B are FWHM in cross-line and in-line direction) have higher uncertainty than specified in TRS-483. Validation tests for Eclipse-TPS generated plans were also performed. The measured dose was in close agreement (3%) with TPS calculated dose up to F.S 1.5 × 1.5cm2.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.