Abstract

On-line measurement of pulverized fuel (PF) distribution between primary air pipes on a coal-fired power plant is of great importance to achieve balanced fuel supply to the boiler for increased combustion efficiency and reduced pollutant emissions. An instrumentation system using multiple electrostatic sensing heads are developed and installed on 510 mm bore primary air pipes of a 600 MW coal-fired boiler for the measurement of mass flow distribution of PF. An array of electrostatic electrodes with different axial widths is housed in a sensing head. An electrode with a greater axial width and three narrower electrodes are used to derive the electrostatic signals for the determination of PF mass flow rate and velocity, respectively. The measured PF velocity is used for the calibration of coal mass flow rate. On-plant comparison trials of the developed system were conducted under typical operating conditions. Isokinetic sampling equipment is used to obtain reference data to evaluate the performance of the system. Experimental data demonstrate that the developed system is effective and reliable for the on-line continuous measurement of PF mass flow distribution between the primary air pipes of the same mill.