Abstract

Among the physical parameters characterising the interaction of the ultrasonic beam with its supporting medium, ultrasonic attenuation is an important input parameter to simulate wave propagation and defect-beam phenomena. The measurement of the intrinsic attenuation in anisotropic material however is a difficult task. The paper presents an approach to determine intrinsic attenuation in anisotropic materials such as austenitic stainless steel welds and cladding. It deals with improvements on the initial device, based on measurements on two samples with different thicknesses (10mm and 20mm). A previous paper presented preliminary results with this new approach for isotropic materials.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.