Abstract
The fracture toughness associated with fibre tensile failure was measured for a T300/920 laminated carbon/epoxy material system using the compact tension specimen configuration. Six methods of data reduction were investigated for calculation of the toughness with the aim of finding the best technique, in terms of reproducibility of results and simplicity. The calculated fracture toughnesses were found to correlate well, though varying amounts of scatter were produced by each method. An optimum method was proposed that does not rely on the use of an optically measured crack length.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.