Abstract

A four microphone intensity probe array has been designed and used to measure two components of the active and reactive acoustic intensity vector. The probe is also used to measure two components of the kinetic energy and the potential energy. Measurements of a point source above a reflecting plane and near the edge of two large reflecting planes were made. These results will be presented and the effects of sensor spacing, probe rotation, proximity of probe to source and boundary, and sensor phase error will be shown and the results will be compared to theoretically predicted values.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.