Abstract

We present the results of the absolute gas gain measurement of a straw drift-tube filled with a binary gaseous mixture Ar-CO2(90-10) at 2 bar absolute pressure. The measurement has been performed using an intense 1.3 GBq 137Cs-source producing the primary ionization current. The results, as a function of the high voltage and gas parameters, were fitted and parameterized with a Diethorn's formula.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.