Abstract

A method is described for measuring the surface shape and deformations of soft tissue in three dimensions. The method uses close range stereophotogrammetry to record the three-dimensional locations of miniature optical targets applied to the tissue surface. This has been applied to study of the human lumbar intervertebral dise. Measurements of the strain along surface annular fibers have been made under varying loads. In this case the maximum expected errors are about 0.15 mm, which corresponds to a strain of less than 1%. Preliminary findings have differed from predictions made in published mathematical models for the disc in that they show very little strain of the annulus in compression loading, but confirm axial torsional loading as liable to produce mechanical disruption of the disc annulus.