Abstract

Liquid-core cylindrical lens (LCL) is glued together by two cylindrical lenses, translucent liquid with refractive index n is injected into the liquid core, based on focal plane imaging method, the refractive index n has a one-to-one dependence on the focal length f of the LCL, n= f(n). Two kind of LCL, symmetrical liquid-core cylindrical lens (SLCL) and asymmetrical liquid-core cylindrical lens (ALCL) had been designed and fabricated, the refractive index measurement accuracy is superior to 0.0002 RIU. Based on the refractive index spatial measurement capability of ALCL, the equivalent refractive index thin layer movement method for rapidly and accurately measuring the diffusion coefficient D under the infinite dilution condition was applied to measure an aqueous CaCl2 solution at temperature of 303 K, and the result D were simulated and verified by ray tracing method. Comparing with the traditional method, this method has the advantages of visualization of diffusion process, strong anti-interference capability, rapid measurement, which can be widely used in medical, chemical, biological, environmental protection or other fields.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.